Mfg Part Number: 049-000207 | Alternate P/N: 049000207 | NSN : 5915-00-849-7430 | NIIN : 008497430 | CAGE Code : 56289 | Manufacturer: Sprague Electric Co | Item Name : Filter Radio Frequency Interfere | FSC : 5915 Filters and Networks |
We appreciate your interest in part 049-000207 of Filter Radio Frequency Interfere. This item, manufactured by Sprague Electric Co with the NSN 5915-00-849-7430, is readily available for immediate purchase. If you would like to receive a personalized quote for comparison, please fill out the Instant RFQ form provided and submit it through this website. Once we have received your request, we will assign an account manager who will formulate a quote in 15 minutes or less and answer any questions.
ASAP Acquire is a preeminent independent distributor of NSN components. National Stock Number (NSN) is a numeric code system created by the United States Military in World War 2. It aimed to create a standardized way of identifying material items in the federal supply chain. The numbers in the 13-digit code help classify the item by federal supply group, country code, and National Item Identification Number. Every part, such as 049-000207, can be searched on our website using its NSN 5915-00-849-7430, manufacturer Sprague Electric Co, or CAGE Code 56289.
We stand by the quality of our products at ASAP Acquire, as they routinely go through our quality assurance program before shipping. This program includes visual inspection, document verification, and cross-referencing of identification codes as necessary. So start the purchasing process with ASAP Acquire today and see what makes us different.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-849-7430 Item Description: Filter Radio Frequency Interfere | 5915 | 008497430 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
049-000207 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.938 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.156 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.938 INCHES NOMINAL |
AECR | III VIBRATION RESISTANCE RANGE IN HERTZ | +5.0 TO 1500.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.3 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.3 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.6 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.6 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBP | III INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE ALL FUNCTIONS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG OUTPUT AND 13 RECTANGULAR FLANGE OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.562 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.562 INCHES NOMINAL |
AFGA | III OPERATING TEMP RANGE | -65.0 TO 125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.3 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.3 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBN | III INPUT TERMINAL MANUFACTURER CODE | 26916 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CBBL | FEATURES PROVIDED | CORROSION RESISTANT AND SHOCK RESISTANT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 RECTANGULAR FLANGE GROUND 3RD FUNCTION |
CQDZ | III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | III BODY MATERIAL | ALUMINUM |
CRDC | III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 200.0 VOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | TWENTY-ONE FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote